Dry Type Transformer
Dry Type Transformer
Dry Type Transformer
Dry Type Transformer
+
  • Dry Type Transformer
  • Dry Type Transformer
  • Dry Type Transformer
  • Dry Type Transformer

Dry Type Transformer


TGT dry-type transformers are the premier choice for indoor and high-sensitivity applications where safety and environmental protection are the top priorities. By utilizing air for cooling instead of combustible fluids, these units provide a reliable, zero-leakage solution that eliminates the risk of fire and environmental contamination. Perfectly suited for urban centers, commercial buildings, and sensitive industrial zones, they offer a safe and sustainable alternative to traditional fluid-filled transformers without compromising on performance.

Rating kVA:

up to 25MVA

Voltage ratings:

up to 35kV

Complant With Standard:

ANSI
IEEE
SA
IEC

info@tgtpower.com

Move in to view details

Dry Type Transformer
Fan Fan Robust fan design enhances cooling capacity, supporting reliable operation under heavy load conditions.
Iron Core Iron Core Carefully assembled by skilled technicians to ensure tight stacking, minimal gaps, and superior magnetic performance.
High-voltage coil High-voltage coil Optimized winding design and epoxy casting process effectively reduce partial discharge and improve dielectric strength.
Low-voltage coil Low-voltage coil Vacuum-cast with epoxy resin for excellent flame resistance, moisture protection, and reliable performance in harsh environments.
  • Product Description

    TGTpower SC(B) series epoxy resin cast dry-type distribution transformers deliver unparalleled fire safety, high environmental adaptability, and maximum structural durability. Engineered specifically for confined space or moisture-prone indoor grids, these eco-friendly assets operate securely without the risk of oil leakages, fluid tracking, or sudden toxic gas release.
    Fully compliant with ANSI/IEEE C57.12.01, IEC 60076-11, and UL 5085-1 benchmarks, our dry-type line brings optimized grid load control and silent thermal dissipation to urban green buildings and high-reliability data centers.

    Key Features

    Maximum Safety

    Non-flammable and explosion-proof—ideal for high-occupancy buildings and tunnels.

    Eco-Friendly

    Zero oil means zero leak risk, protecting your site from environmental hazards.

    Indoor Optimized

    Compact design and air-cooled efficiency make them perfect for restricted spaces.

    Low Maintenance

    No fluid testing or replacement required, reducing your long-term operational costs.

    Technical Data for 20kV dry type transformer three phase double-winding (NLTC)

    Rated Capacity (kVA)

    Rated voltage and tapping range

    Vector group

    No load Current (%)

    Impedance voltage (%)

    No load Losses (KW)

    On load losses (W)

    HV(kV)

    Tapping range(%)

    LV(kV)

    B (100℃)

    F (120℃)

    H (145℃)

    50

    20
    22
    24

    ±2×2.5
    ±5

    ±2×2.5
    ±5

    Yyn0
    Dyn11

    1.8

    6.0

    305

    1160

    1230

    1310

    100

    485

    1870

    1990

    2130

    160

    1.4

    600

    2330

    2470

    2640

    200

    655

    2770

    2940

    3140

    250

    755

    3220

    3420

    3660

    315

    870

    3850

    4080

    4360

    400

    1.0

    1030

    4650

    4840

    5180

    500

    1210

    5460

    5790

    6190

    630

    1370

    6450

    6840

    7320

    800

    1570

    7790

    8260

    8840

    1000

    0.80

    1860

    9220

    9780

    10400

    1250

    2140

    10800

    11500

    12300

    1600

    2510

    13000

    13800

    14800

    2000

    0.60

    2910

    15400

    16300

    17500

    2500

    3480

    18200

    19300

    20700

    Technical Data for 10kV dry type transformer three phase double-winding (NLTC)

    Rated Capacity (kVA)

    Rated voltage and tapping range

    Vector group

    No load Current (%)

    Impedance voltage (%)

    No load Losses (W)

    On load losses (W)

    HV(kV)

    Tapping range(%)

    LV(kV)

    B (100℃)

    F (120℃)

    H (145℃)

    30

    6
    6.3
    6.6
    10
    10.5
    11

    ±2.5 ±5

    6
    6.3
    6.6
    10
    10.5
    11

    Yyn0
    Dyn11

    2.0

    4.0

    105

    605

    640

    685

    50

    155

    845

    900

    965

    80

    1.5

    210

    1160

    1240

    1330

    100

    230

    1330

    1415

    1520

    125

    270

    1565

    1665

    1780

    160

    310

    1800

    1915

    2050

    200

    ±2×2.5 ±5

    1.1

    360

    2135

    2275

    2440

    250

    415

    2330

    2485

    2665

    315

    510

    2945

    3125

    3355

    400

    570

    3375

    3590

    3850

    500

    0.80

    670

    4130

    4390

    4705

    630

    775

    4975

    5290

    5660

    630

    6.0-8.0

    750

    5050

    5365

    5760

    800

    0.70

    875

    5895

    6265

    6715

    1000

    1020

    6885

    7315

    7885

    1250

    1205

    8190

    8720

    9335

    1600

    1415

    9945

    10555

    11320

    2000

    0.60

    1760

    12240

    13005

    14005

    2500

    2080

    14535

    15445

    16605

    Certification Certificate

    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun

    Core Advantage Of TGTpower Dry type Transformers

    Exceptional Fire & Explosion Safety

    The thin-layer epoxy resin cast coils are entirely flame-retardant, self-extinguishing, and explosion-proof, satisfying the most rigid localized fire-protection codes. 

    Class H DuPont NOMEX® Insulation

    Windings can be custom-insulated with genuine Class H (180°C) DuPont NOMEX® matrices, ensuring superb dielectric strength and anti-thermal-shock resilience under aggressive overloading. 

    Step-Lap Low-Noise Design

    Core cutting utilizes precision step-lap progressive joints to smoothly optimize magnetic flux distribution, dampening operational acoustic humming far below standard NEMA indices.  

    Moisture-Resistant & Dust-Proof Armor

    Coils undergo multiple Vacuum Pressure Impregnation (VPI) lacquer cycles, enabling the transformer to re-energize smoothly after long standbys in 100% relative humidity without initial pre-drying. 

    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Packaging

    Hermetic Anti-Moisture Barrier Package:

    Every dry-type unit is completely enveloped inside an industrial-grade, thick polymeric thermal shrink-wrap layer, incorporating active industrial desiccants to permanently absorb air humidity during oceanic container transport.  
    Reinforced Shock-Proof Cushion Skids:

    The active transformer assembly is secured tightly with heavy-duty tensioning straps onto solid wood skid platforms (fully compliant with ISPM 15 Fumigation-Free standard) to completely absorb maritime structural shaking and transit vibrations.

    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun

Product Inquiry

If you need a professional consultant familiar with your market to provide one-on-one services, please leave your contact information.

%{tishi_zhanwei}%