Single Phase Pole Mounted
Single Phase Pole Mounted
Single Phase Pole Mounted
Single Phase Pole Mounted
Single Phase Pole Mounted
Single Phase Pole Mounted
Single Phase Pole Mounted
Single Phase Pole Mounted
+
  • Single Phase Pole Mounted
  • Single Phase Pole Mounted
  • Single Phase Pole Mounted
  • Single Phase Pole Mounted
  • Single Phase Pole Mounted
  • Single Phase Pole Mounted
  • Single Phase Pole Mounted
  • Single Phase Pole Mounted

Single Phase Pole Mounted


Engineered to strictly satisfy the rigorous efficiency thresholds of DOE 2016 (USA) and CSA 2023 (Canada), TGTpower’s single-phase series offers optimized performance metrics, compacted frame weights, and zero-compromise environmental sustainability for residential and decentralized workloads.

Rating kVA:

Up to 333kVA

Voltage ratings:

Up to 34.5 kV

Complant With Standard:

ANSI
IEEE
SA

info@tgtpower.com

Move in to view details

Single Phase Pole Mounted Transformer
Active part assembly Active part assembly Precisely assembled with tight tolerances, ensuring excellent electrical performance, structural integrity, and long-term reliability.
Bushing Bushing Provides safe electrical insulation and reliable current transfer between the transformer and external circuits.
  • Product Description

    Engineered to strictly satisfy the rigorous efficiency thresholds of DOE 2016 (USA) and CSA 2023 (Canada), TGTpower’s single-phase series offers optimized performance metrics, compacted frame weights, and zero-compromise environmental sustainability for residential and decentralized workloads.

    Key Features

    Flexible Configuration

    Single-phase units can be used alone for localized loads or clustered together for high-performance three-phase power.

    Versatile Installation

    Seamlessly mounts to either wooden or concrete poles, supporting both individual and clustered deployment.

    Full Compliance

    Tested to rigorous IEEE standards, ensuring long-term reliability in challenging environments.

    Residential Optimization

    Specifically engineered for residential overhead distribution, delivering stable and efficient power where it's needed most.

    Single Phase Pole Mounted Transformer

    Rated Capacity (KVA)

    Voltage Combination

    Loss (W)

    Size (mm)

    DOE2016
    Efficiency (%)

    High Voltage (V)

    Low Voltage (V)

    Tapping Ranges

    No-load Loss (w)

    On-load Loss (w)

    Length

    Width

    higth

    15

    2400
    4160
    7200
    7620
    12000
    12470
    13200
    13800
    14400
    19920
    24940
    34500

    110
    120
    208
    240
    277
    347
    415
    416
    480
    600
    690

    ±2*2.5%

    60

    80

    100

    120

    130

    150

    330

    370

    450

    620

    850

    1150

    520

    560

    610

    635

    754

    770

    795

    565

    590

    625

    975

    840

    890

    965

    905

    935

    935

    1035

    1035

    1135

    1135

    98.82

    25

    98.95

    37.5

    99.05

    50

    99.11

    75

    99.19

    100

    99.25

    167

    99.33

    250

    99.39

    333

    99.43

    500

    99.49

    Certification Certificate

    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun

    TGTpower Pad-Mounted Transformers Project Application

    From executing extensive rural electrification retrofits across rugged terrains to scaling overhead residential utility grids, TGTpower’s certified completely self-protected (CSP) single-phase pole-mounted transformers provide uncompromised grid security, lightning-proof resilience, and maintenance-free longevity under the most severe global weathering conditions.

    Hoardsun
    Hoardsun
    Hoardsun

    Engineered with low-loss wound cores for direct wood or concrete pole suspension installation. Available as Conventional units or completely integrated CSP (Completely Self-Protected) setups containing direct-connected primary protection fuses, direct surge arresters, and over-oil secondary circuit breakers to isolate the system from sudden distribution failures.  
    Porcelain Bushings: Top-mounted or side-mounted wet-process porcelain high-voltage bushings designed with premium insulation resistance to eliminate lightning flashover risks. 

    Optional

    Dual-Voltage Tap Changer Switch

    Deployed as primary step-up substation units up to 720MVA capacity, seamlessly synchronizing bulky electricity output from multi-GW wind and solar generation fields into high-voltage continental transmission grids.  

    Completely Self-Protected (CSP) Accessory Suite (Optional)

    Includes tank-mounted MOV surge arresters, oil-immersed weak-link primary protective fuses, and an over-oil secondary circuit breaker accompanied by an external thermal overload signal light.  

    Hoardsun
    Hoardsun
    Hoardsun
    Hoardsun

Prev

Next

Product Inquiry

If you need a professional consultant familiar with your market to provide one-on-one services, please leave your contact information.

%{tishi_zhanwei}%